IOM Sampler/Cassette, Plastic
& Related Items
Print this Page!   

IOM Sampler

A Gold Standard for Personal Inhalable Particulate Sampling

Meets U.S. and international standards
  • ACGIH sampling criteria for inhalable particulate mass
  • Preferred sampler for HSE Method MDHS 14/3
  • NIOSH Method 5700 for particulate formaldehyde
  • Australia standard for inhalable particulate
  • Complies with MDHS 25/3 for organic isocyanates
  • Complies with MDHS 6/3 for lead

Economical and reusable

Small and lightweight

  • Plastic model weighs less than 2 oz (55 gm)
Efficient particulate sampling up to 100 µm

IOM Sampler Cat. No. 225-70 Attached to Worker

Maintains sample integrity

  • Removable 25-mm cassette system eliminates filter handling
  • Cassette and filter are weighed as a single unit to include all collected particles in analysis

Sampler and cassette available in stainless steel
  • Provides ultimate moisture stability and autoclaving at higher temperatures

Improved plastic material significantly reduces effects of moisture

Stainless steel sampler and cassette available

 

Performance Profile

IOM Sampler Cat. No. 225-70 Sample Time Varies
Flow Rate 2 L/min (personal sampling)
Construction Molded conductive plastic or stainless steel; both are autoclavable
Sample Pump PCXR Series
Filters 25-mm membrane or fibrous filter
Analysis Gravimetric
50% Cut Point 100 µm at 2 L/min inhalable fraction
Weight (without cassette) 0.7 oz. (20 gm)
Size 3.3 x 1.1 in (8.5 x 2.8 cm)

 

 

 

 

 

 

 

 

 

IOM Product Data Bulletin (PDF)

IOM Operating Instructions (PDF)


IOM Sampler

The patented* IOM Sampler, developed by J. H. Vincent and D. Mark at the Institute of Occupational Medicine (IOM) in Scotland, meets the ACGIH sampling criteria for inhalable particulate mass. The IOM Personal Inhalable Sampler is a conductive plastic sampling head that houses a reusable 25-mm filter cassette with specified filter for the collection of inhalable airborne particles. When attached to a personal sampling pump operating at 2 L/min and clipped near a worker's breathing zone, the IOM effectively traps particles up to 100 µm in aerodynamic diameter and closely simulates the manner in which airborne workplace particles are inhaled through the nose and mouth. Because both the cassette and the filter are pre and post-weighed as a single unit, all particles collected (even larger ones) are included in the analysis. The cassette can be cleaned, reloaded with a new filter, and reused.

* U.S. Patent No. 4,675,034


Exploded View of the IOM Inhalable Dust Sampler 225-70A

Exploded View of the IOM Inhalable Dust Sampler


 

Particle Size-selective Dust Sampling

The hazard potential of airborne dust, solid particles, or droplets is dependent on the mass concentration as well as the particle size. Particle size determines the deposition site within the respiratory tract and the subsequent health effect. Therefore, the American Conference of Governmental Industrial Hygienists (ACGIH®), has recommended that particle-size selective Threshold Limit Values (TLV®s) be developed for inhalation hazards in the workplace.

Particle-size selective TLVs consider two points:
  1. The size-fraction most closely associated with the specific health effect.
  2. The mass concentration within that size fraction which should represent the TLV.
The ACGIH recommends that particle-size selective TLVs be expressed in three forms:

ACGIH recommends that particle-size figure
Inhalable Particulate Mass
Dust particles having a 50% cut-point of 100 µm. These dust particles are hazardous when deposited anywhere in the respiratory tract.

Thoracic Particulate Mass
Dust particles having a 50% cut-point of 10 µm. These dust particles are hazardous when deposited anywhere in the lung airways and gas-exchange regions.

Respirable Particulate Mass
Dust particles having a 50% cut-point of 4 µm. These dust particles are hazardous when deposited anywhere in the gas-exchange regions.
Since inhalable particulate mass is defined as those materials that are hazardous when deposited anywhere in the respiratory tract, including the nose and mouth, a sampler designed for the collection of inhalable dust should have a median cut-point of 100 µm.

Ordering Information          

IOM Samplers, use with filter, select from below Cat. No.
IOM Sampler and Cassette, in conductive plastic, with transport clip and cover IOM Sampler and cassette 225-70 225-70A
IOM Sampler and Cassette, in stainless steel, with transport clip and cover 225-76A
IOM Sampler, in conductive plastic, with stainless steel cassette, transport clip, and cover 225-79A
PCXR4 Single 115 V Pump Kit with IOM, does not include cassette holder 224-PCXR4PK
Accessories Cat. No.
Cassette Assembly, in conductive plastic, with transport clip and cover  Conductive plastic cassette 225-71A 225-71A
Cassette Assembly, in stainless steel, with transport clip and cover Stainless steel cassette 225-75A 225-75A

Transport Clip with cover for cassette. Protects loaded filter cassette without IOM body during transportation (Shown with stainless steel cassette, not included)

Trasnspor clip and cap 225-72A 225-72A
Calibration Adapter, easy to use; simple and accurate calibration
Calibration adapter 225-73
25mm Filters
Each sample requires its own filter.
Pore size
Quantity
Cat. No.
Polyvinyl Chloride (PVC) 5.0 µm  100 225-8-04
Glass Fiber 1.0 µm 500 225-702
Mixed Cellulose Ester (MCE) 0.8 µm 100 225-1930
Polycarbonate 0.8 µm 100 225-1601
Gelatin   50 225-9551

IOM Product Data Bulletin (PDF)

IOM Operating Instructions (PDF)

IOM FAQs


References

Mark, D. and Vincent, J. H., "A New Personal Sampler for Airborne Total Dust in Workplaces," Ann. Occup. Hyg. Vol. 30,1986, pp. 89-102.

ACGIH Technical Committee on Air Sampling Procedures: Particle Size-selective Sampling in the Workplace, ACGIH, Cincinnati, Ohio, 1984.


This page was last modified March 18, 2008

Print this Page!

 

SKC GULF COAST Inc.
1-800-225-1309


 About Us
 Terms of Use
 Privacy Policy
 Feedback
 
Home |  What's New |  Search |  Online Store |  Products |  Quotes |  Literature |  Technical Library
Downloads |  How to Order |  Events |  About Us |  Contact Us |  Links |  Site Map  | SKC Lite

Copyright © SKC Gulf Coast Inc., 2008, All Rights Reserved