? 
Advanced Search
What's New
Online Store
Products
    Online Product Catalog
    Sample Pumps
    Active Air Sampling
    Passive Sampling
    Particulate Sampling
    Portable Instruments
    Bioaerosol Sampling
    Surface Sampling
    Specialty Sampling
    References & Training
    Rental Program
Quick Quotes
Literature
Technical Library
Downloads
How to Order
Events Calendar
Homeland Security
Hurricane Clean-up
Presentations
Related Links
Home Page

Stay informed!
Sign up for our eNewsletter
Name:

Email Address:

Manage Subscription

GSA Federal Supply Schedule

Set Viewing Preference


Coated Filters
Coated Filters in Preloaded Cassettes

 

SKC Saves you time and money
with coated filters in preloaded cassettes

  • Easy-to-use
  • Convenient
  • Economical
  • No assembly required
  • Meet NIOSH, OSHA, and ASTM method specifications
Coated Filters in Preloaded Cassettes

For your convenience, SKC manufactures coated filters for a wide variety of air sampling methods that require chemically-treated filters or pads. SKC Coated Filters are shipped inside the cassettes with end plugs and sealing bands in place. No assembly is required; they are ready to use.

To use coated filters, simply remove the end caps and connect the cassette to the sampling pump using Tygon tubing. Remove the inlet section if sampling open face. After sampling, remove the cassette and replace the end caps or entire inlet section. Record the flow rate and sample time, then send the filter cassettes and sampling information to a lab for analysis.

Coated Filter Selection Chart
Chemical Analytical Method Filter and Coating
Coated filters have a limited shelf life
Cassette
with sealing bands
Cat. No. Qty
Acetic anhydride OSHA 82 Glass-filters;-1-(2-pyridyl)-piperazine 4-piece,
37 mm
225-9009 • 10
Acetic anhydride OSHA 102 Glass filters; veratrylamine and di-n-octyl phthalate 4-piece,
37 mm
225-9010† 10
4-Aminobiphenyl OSHA 93 Glass filters; sulfuric acid 3-piece,
37 mm
225-9004 10
Aniline NIOSH 2017 Glass filters; sulfuric acid 3-piece,
37 mm
225-9004 10
Arsenic volatile compounds OSHA ID 105 MCE filter & cellulose pad; sodium carbonate 3-piece,
37 mm
225-9001 10
Benzidine OSHA 65 Glass filters; sulfuric acid 3-piece,
37 mm
225-9004 10
Bromine NIOSH 6011
Teflon pre-filter & porous plastic support; specially-cleaned silver membrane & porous plastic support
3-piece,
25 mm
225-9006 5
Chlorine NIOSH 6011 Teflon pre-filter & porous plastic support; specially-cleaned silver membrane & porous plastic support 3-piece,
25 mm
225-9006 5
Crotonaldehyde OSHA 81 2 Glass filters; 2,4-dinitrophenylhydrazine and phosphoric acid 3-piece,
37 mm
225-9019 • 10
o-Dianisidine OSHA 71 Glass filters; sulfuric acid 3-piece,
37 mm
225-9004 10
3,3'-Dichlorobenzidine OSHA 65 Glass filters; sulfuric acid 3-piece,
37 mm
225-9004 10
Diisocyanates —
1,6-Hexamethylene diisocyanate (HDI), Toluene-2,4-diisocyanate (2,4-TDI ), Toluene-2,6-diisocyanate (2,6-TDI)
OSHA 42 ‡ Glass filter & cellulose support; 1-(2-pyridyl) piperazine‡ 3-piece,
37mm
225-9002 ‡•
or
225-9013‡•
10
Diisocyanates —
Toluene-2,4-diisocyanate (2,4-TDI ), Toluene-2,6-diisocyanate (2,6-TDI)
ASTM D5836 ‡ Glass filter & cellulose support; 1-(2-pyridyl) piperazine‡ 3-piece,
37mm
225-9002 ‡•
or
225-9013‡•
10
Diisocyanates
(NDI, etc)
MDHS 25/3 (UK) AE Glass filters; methoxyphenyl piperazine 25 mm filters only, not in preloaded cassettes 225-9011• 5
Diphenylamine OSHA 78 Glass filters; sulfuric acid 3-piece,
37 mm
225-9004 10
Fluorides OSHA ID 110
NIOSH 7902
NIOSH 7906
ASTM D4765
MCE filter & cellulose pad; sodium carbonate 3-piece,
37 mm
225-9001 * 10
Fluoride, particulates EPA 14A
not
EPA TO-14A
2 PVC filters & supports; sodium formate/ Metricel filter; uncoated 4-piece,
37 mm
225-9016 10
Glutaraldehyde OSHA 64 Glass filters; 2,4-dinitrophenyl hydrazine 4-piece,
37 mm
225-9003• 10
Hydrazine OSHA 108 Glass filters; sulfuric acid 3-piece,
37 mm
225-9012 10
N-Isopropylaniline OSHA 78 Glass filters; sulfuric acid 3-piece,
37 mm
225-9004 10
Maleic Anhydride OSHA 86 Glass filters; veratrylamine 3-piece,
37 mm
225-9021 10
Mercaptans
(methyl-, ethyl- and n-butyl-)
NIOSH 2542 Glass filter; mercuric acetate 2-piece,
37 mm
225-9007 10
4,4'-Methylene bis (2-chloroaniline) (MOCA) OSHA 71 Glass filters; sulfuric acid 3-piece,
37 mm
225-9004 10
Methylene bisphenyl isocyanate (MDI) OSHA 47 ‡ Glass filter & cellulose support; 1-(2-Pyridyl) piperazine‡ 3-piece,
37mm
225-9002 ‡•
or
225-9013 ‡•
10
4,4'-Methylenedianiline OSHA 57 Glass filters; sulfuric acid 3-piece,
37 mm
225-9004 10
1-Naphthylamine OSHA 93 Glass filters; sulfuric acid 3-piece,
37 mm
225-9004 10
2-Naphthylamine OSHA 93 Glass filters; sulfuric acid 3-piece,
37 mm
225-9004 10
Nitrobenzene NIOSH 2017 Glass filters; sulfuric acid 3-piece,
37 mm
225-9004 10
Ozone OSHA ID 214 2 Glass filters; nitrite-impregnated 3-piece,
37 mm
225-9014† 10
N-Phenyl 1-Naphthalymine OSHA 96 Extra thick glass filters; ascorbic acid 3-piece,
25 mm
225-9015 5
N-Phenyl 2-Naphthalymine OSHA 96 Extra thick glass filters; ascorbic acid 3-piece,
25 mm
225-9015 5
Phenylene diamine
(o-, m-, p-)
OSHA 87 Glass filters; sulfuric acid 3-piece,
37 mm
225-9004 10
Phosphine OSHA 1003 Glass filter; untreated
Polyester filter; mercuric chloride
3-piece,
37 mm
225-9018† 10
Sulfur dioxide NIOSH 6004 # MCE pre-filter & support/cellulose filter & support; sodium carbonate 3-piece,
37 mm #
225-9005 10
2,4-Toluendiamine OSHA 65 Glass filters; sulfuric acid 3-piece,
37 mm
225-9004 10
2,6-Toluendiamine OSHA 65 Glass filters; sulfuric acid 3-piece,
37 mm
225-9004 10
o-Toluidine NIOSH 2017 Glass filters; sulfuric acid 3-piece,
37 mm
225-9004 10
o-Tolidine OSHA 71 Glass filters; sulfuric acid 3-piece,
37 mm
225-9004 10
Toluidine
(o-, m-, p-)
OSHA 73 Glass filters; sulfuric acid 3-piece,
37 mm
225-9004 10
Valeraldehyde OSHA 85 3 Glass filters; 2,4-dinitrophenylhydrazine and phosphoric acid 3-piece,
37 mm
225-9020 • 10
m-Xylylenediamine and
p-Xylylenediamine
(m-XDA, p-XDA)
OSHA 105 Glass filters; sulfuric acid 3-piece,
37 mm
225-9004 10

Table Notes

• Freezer storage required.

† Special order due to limited shelf-life.

‡ OSHA Method 42 specifies a filter loading of 0.1 mg of 1-(2-pyridyl) piperazine, and OSHA 47 and ASTM D5836 each specify a filter loading of 1 mg of 1-(2-pyridyl) piperazine; however CF/CST 225-9002 and 225-9013 are acceptable for all of these sampling methods
  • 225-9002: Loading of 1-(2-pyridyl) piperazine increased to 2 mg to increase stability and shelf-life of filters.

  • 225-9013: Loading of 1-(2-pyridyl) piperazine is 1 mg.


# NIOSH Method 6004 modified. Single 3-piece cassette replaces two 2-piece cassettes in series following 1993 NIOSH revisions. Reference: Lorberau, Charles, "Determination of Gaseous and & Series Particulate Fluorides by Ion Chromatographic Analysis," Applied Occupational and Environmental Hygiene 8 (9) 1993, pp. 775-784.

NIOSH Method 2017 also requires SKC Sorbent Tube Catalog Number 226-15

• Filters only; not in preloaded cassettes

* The concept of sampling for fluorides in air using a double filter is patented in Canada by IRSST (Institut de recherche en sant้ et en s้curit้ du travail du Qu้bec), 21-April-92, Patent No. 1,299,114.

Custom Filters Available

For specific applications, SKC will manufacture filters to meet your specific requirements. Contact us for more information.

 

SKC GULF COAST Inc.
1-800-225-1309


 About Us
 Terms of Use
 Privacy Policy
 Feedback
 
Home |  What's New |  Search |  Online Store |  Products |  Quotes |  Literature |  Technical Library
Downloads |  How to Order |  Events |  About Us |  Contact Us |  Links |  Site Map  | SKC Lite

Copyright ฉ SKC Gulf Coast Inc., 2008, All Rights Reserved