VAC-U-GO Sampler
For Flows up to 30 L/min and Sonic Flow Applications

The Vac-U-Go non-compensating vacuum pump is a rotary vane-type pump that provides
flows
up
to
30
L/min
and
maintains sonic flow when used with the SKC
BioSampler. The
AC-powered
Vac-U-Go
features
a protective housing with handle and can be used for a variety of ambient and
indoor air sampling applications including asbestos, bioaerosol, stack, VOC,
and
fenceline monitoring. It is ideal for sampling bioaerosols using the
BioSampler or the AGI-30 Impinger. The SKC BioSampler does not require
a critical orifice accessory for sonic flow.
The line-operated Vac-U-Go Sampling pump has a permanently lubricated
motor that is mounted in a housing with a vacuum pressure gauge
to indicate sonic flow and a throttling valve to adjust flow. Both
models are supplied with an extension rod for mounting media and
a power cord.
The Vac-U-Go Sampler can be operated in two different modes: non-compensating
and BioSampler. Vac-U-Go is non-compensating, therefore, it is
not suitable for compliance sampling in non-sonic mode. For indoor
air studies, compliance, or other applications that require a quiet,
compensating vacuum pump, use the QuickTake 30 or Quicktake 15 Sample
Pump.
Note: Sonic flow is attained when a vacuum pump pulls
air through an orifice to create a condition where the downstream
pressure is 52% of the upstream
pressure. At this point, air velocity through the orifice has reached
the speed of sound and cannot increase, therefore, the orifice
becomes
"critical." The fixed air velocity at the critical orifice also
limits the airflow so that the condition remains constant regardless
of pressure variations in the system. Airflow will remain constant
at vacuum levels >15 inches Hg.
VAC-U-GO
Operating Instructions (PDF)
Vac-U-Go
CE Conformity Declaration (PDF)
Performance Profile
| Flow range: |
Non compensated airflow up to 30 L/min
Sonic flow with BioSampler (acts as a critical orifice) is approximately
12.5 L/min |
| Motor: |
Oil-less rotary vane |
| Vane life: |
Approximately 6000 to 27,000 hrs depending on application |
| Power: |
Line power only
115V, AC, 60 Hz (Cat. No. 228-9605)
230V, AC, 50 Hz (Cat. No. 228-9605B) |
| Operating temperature range: |
32 to 104 F (0 to 40 C) |
| Size: |
5.5 x 10.5 x 6.5 ins. (13.9 x 26.7 x 16.5 cm) |
| Weight: |
12 lbs (5.4 kg) |
| Standards: |
None. Pump is not intrinsically safe. |
Ordering Information
Description
|
Cat. No. |
Vac-U-Go Sampling Pump
Mounted in protective housing with vacuum gauge and valve to assure sonic
flow performance. Supplied without orifices or rotameter. AC operation
only 115 V
Recommended for use with the SKC
BioSampler. No critical orifice is needed if used with a BioSampler. |
228-9605
|
Vac-U-Go Sampling Pump
Mounted in protective housing with vacuum gauge and valve to assure sonic flow
performance. Supplied without orifices or rotameter. AC operation only 230 V
Recommended for use with the SKC
BioSampler. No critical orifice is needed if used with a BioSampler. |
228-9605B |
| Certificate of Compliance, optional, must
be ordered when ordering pump |
P1501 |
| Accessories |
L/min |
Cat. No. |
| Field Rotameter |
4 to 50 |
320-440 |
VAC-U-GO
Operating Instructions (PDF)
Vac-U-Go
CE Conformity Declaration (PDF)
This page was last modified July 14, 2008
|