The AirChek 2000
Air Sampling Pump
PC
Programmable with Flows to 3250 ml/min
|
|
Li-ion models
|
AirChek
2000 Spec. Sheet (PDF)
AirChek
2000 Operating Instructions (PDF)
AirChek 2000 Quick Guide (PDF)
CalChek
with the Defender Operating Instructions (PDF)
Battery
Pack for AirChek
2000 Operating Instructions (PDF)
MSDS
for Nickel Cadmium Battery GPI International (PDF)
MSDS
for Nickel Cadmium Battery SANYO Energy (PDF)
MSDS
for Nickel-metal Hydride Battery (PDF)
Technical
Note: SKC Sample Pump Battery Pack Characteristics and Maintenance
(PDF)
DataTrac
2000 Software Package
UL
Certificate of Compliance (PDF)
EMC
Test Certificate (PDF)
KEMA
(Keuring van Electrotechnische Materialen) Certificate of Conformity
(PDF)
Instrucciones
de Operación (PDF)
Bedienungsanleitung
(Kurzfassung)(PDF)
Téléchargement
Guide de I'utilisateur (PDF)
Chinese
Language AirChek 2000 Operating Instructions (PDF)
Schedule it on a PC!
Combine AirChek 2000, your PC, and DataTrac 2000 Software to easily create single
or multiple sampling schedules that include delayed start, timed shutdown,
and sequential
sampling. Alternatively , a single schedule can be set manually using the pump's
large integral keypad.
Sample and record it!
Start sampling with the click of a mouse or the press of a button. A patented
(U.S. Patent No. 5,892,160)
internal flow sensor acts as a secondary standard to accurately maintain set
flow. AirChek 2000 records flow rate, run time, sample volume, and flow fault
throughout
the
sampling period. View values on a PC in pump history or during sampling on the
pump LCD.
Download and report it!
Use your PC and DataTrac 2000 Software to download pump history, import data into your favorite software for IH lab reporting, or create a worker exposure profile for complete reporting.
CalChek it!
The CalChek feature provides direct communication between an AirChek 2000 pump
and a Defender primary standard calibrator. This results in highly accurate single-point
calibration for pre and post-sampling and complete multiple-point calibration
following pump maintenance.
Partner the AirChek 2000 pump and CalChek with your PC and DataTrac 2000 Software
for documented results of
calibration for ISO 9000, Total Quality Management programs, and occupational
health and safety management systems.
Patented* isothermal flow control
system
Accurate internal flow sensor measures flow directly and acts as a secondary
standard to maintain set flow with an accuracy of ± 5%. Thermal and pressure
sensors maintain
flow
calibration
by compensating for differences between the temperature and atmospheric pressure
at calibration and those
during sampling.
* US Patent No. 5, 892, 160
Long run times
With NiMH battery pack, run time is 12+ hours at 2000 ml/min and up to 30 inches
water
back pressure; dependent on sample media used
Battery status display
Indicates battery power available
to operate pump
Wide flow range - 5 to 3250 ml/min
AirChek 2000 is the best choice for many sampling applications.
Low flow capability
With the easy-to-use low flow adapter kit, achieve flows from 5 to 500 ml/min (low flow does not include some electronic readout options).
Easy PC programmability
Combine AirChek 2000 and a PC with DataTrac 2000 Software to easily create
multiple sampling schedules that include delayed start, timed shutdown, and
sequential sampling or download sampling data to a PC
for storage and analysis.
Compact, lightweight, and ultra-quiet
For greater worker acceptance
Intrinsic safety
Versatile for all industries and safe in explosive environments; UL and cUL Listed
Continuous sample volume calculations
Flow-rate, run time, volume, and flow fault are continuously recorded for
accurate sample reporting.
RFI/EMI-shielded, impact-resistant case
Ensures accurate air volumes and data validity; covers protect battery charging
jack and computer interface port; CE marked
Security system protects data
A security code minimizes accidental changes and maintains sample validity.
Multiple-tube sampling feature
Save valuable time with simultaneous 2, 3, or 4-tube sampling
Protective features
Auto shut-off at low battery; automatic flow fault shutdown and restart


Advanced Automatic Calibration Feature!
Direct Communication to a Primary Standard
The patented (U.S. Patent
Nos. 6,227,031 and 6,363,769) CalChek automatic
calibration feature makes it easy to calibrate an AirChek 2000 pump to the desired
flow rate using a Defender calibrator without manual adjustments (requires
an
AirChek 2000 pump [version 2.59 or higher], a Defender calibrator, and CalChek
communication
cable).
Optional DataTrac 2000 Software (version 3.62 or higher) can be used to expand
the documentation capabilities of this system. CalChek allows automatic field
calibration,
reduces the need for frequent factory calibration,
and provides two calibration options. Both types of calibration bring flow to
within 5%.
- Single-point Calibration allows setting and verifying a
flow rate at a single point before and after sampling.
- Multiple-point (Full) Calibration corrects flow to a primary
standard at multiple flow rates to cover the basic operational flow range of
the pump.
Fast, simple, and accurate calibration
No timers, soap film, or delicate equipment needed. The tough Defender calibrator
with built in DryCal technology provides an automatic, accurate flow rate
average that you can count on.
No manual adjustments
The CalChek feature provides direct communication between the AirChek 2000
Sample Pump and the Defender calibrator. No user intervention is needed. Simply
set up the calibration train and push a button to start automatic calibration.
CalChek - two calibration options
With CalChek, quickly calibrate flow at a single point before and verify flow after sampling or calibrate the pump across a range of flows following repair and maintenance to ensure optimum pump performance.
Complete documentation of calibration for ISO 9000, TQM programs, and OHS management systems
CalChek, used with DataTrac Software, allows the user to download data to a PC and generate printed reports for complete documentation.
AirChek 2000
Easy PC Programmability

The SKC AirChek 2000 pump, Windows-based DataTrac
2000 Software, and your
PC are an unbeatable combination for creating multiple sampling schedules
that include delayed start, timed shutdown, and sequential sampling and a
complete documentation of sampling history.

With
DataTrac 2000:
- Create a sample and analysis sheet for all critical information.
- Program a complete running sequence, delayed start, timed shutdown, or intermittent
sampling even at different flow rates.
- Program single or multiple sampling schedules.
- Save an AirChek 2000 program.
- Access complete documentation of calibration when used with CalChek feature.
- Download sampling data to a PC and import into word processing software to create a complete report.
- With CalChek, download calibration data for complete documentation for ISO, TQM programs, or occupational health and safety management systems.
To learn more about the DataTrac software, click
here to go to the DataTrac page.
AirChek 2000
Easy Operation and Long Run Times
Large easy-to-read LCD  |
Continuously updated sampling data displays on the AirChek
2000 large
LCD. With the press of a single button, scroll through flow rate, air volume,
run time, temperature, atmospheric pressure, battery status, time of day,
and flow fault. A battery status icon constantly displays and a flow fault
icon flashes during restricted or blocked flow. A flashing LED on top of
the pump indicates the pump is running in low-light or loud environments. |
Easy Manual Programming
It's right on the front of the pump. Set flow rate and run time without screwdrivers;
simply use the 3-button keypad. A convenient timed shutdown feature allows you
to program the AirChek 2000 to run for a set time from 1 to 999 minutes, a very
useful feature for STELs or repetitive sample runs.
|
Simple 3-button Keypad |
Flow Fault Features:
- Auto shut-off with low battery or excessive back pressure
- Adjustable flow fault shutdown from 5 seconds to 4 minutes
when used with a PC and DataTrac 2000 Software
- Auto-restart from flow fault attempted every 5 minutes
for a maximum of 10 times (can be changed with DataTrac 2000 Software)
- Run time data stored in memory
AirChek 2000 Run Time in Hours with NiMH Battery
Following are typical run times achieved when using a fully charged nickel-metal
hydride (NiMH) battery pack. Data is sorted by type of sample media. All run
times are listed in hours. Results are obtained using a new pump and new fully
charged battery. Pump performance may vary.
Mixed Cellulose Ester (MCE) filter, 0.8-µm pore
size
Flow
Rate (L/min)
|
Filter
Diameter
|
|
37 mm
|
25 mm
|
2.0
|
37
|
32
|
2.5
|
33
|
26
|
3.0
|
30
|
21
|
Polyvinyl Chloride (PVC) filter, 5.0-µm pore
size
Flow
Rate (L/min)
|
Filter Diameter
|
|
37 mm
|
25 mm
|
2.0
|
44
|
40
|
2.5
|
36
|
34
|
3.0
|
31
|
27
|
Increases in back pressure during sampling due to buildup of sample on the
filter can decrease battery life.
AirChek 2000 Run Time in Hours with NiCad Battery
AirChek 2000 provides long run times for sampling flexibility. Tests*
show the following run times at 2 L/min. All run times are listed in hours.
Mixed Cellulose Ester (MCE) filter, 0.8-µm pore
size
Flow Rate (L/min)
|
Filter Diameter
|
|
37 mm
|
25 mm
|
2.0
|
24.2
|
15.2
|
2.5
|
20.4
|
12.4
|
3.0
|
17.7
|
**
|
Polyvinyl Chloride (PVC) filter, 5.0-µm pore
size
Flow Rate (L/min)
|
Filter Diameter
|
|
37 mm
|
25 mm
|
2.0
|
28.2
|
21.8
|
2.5
|
27.0
|
22.0
|
3.0
|
22.6
|
18.2
|
| * |
Results
obtained using a new pump and new fully charged battery. Pump performance
may vary.
|
| ** |
Filter back
pressure exceeded pump capability during testing. |
Performance Profile
AirChek 2000 |
| Flow Range |
1000 to 3250 ml/min
(5 to 500 ml/min requires optional low flow adapter kit) |
| Compensation
Range |
3000 ml/min at 15 inches water back pressure
2000 ml/min at 30 inches water back pressure
1000 ml/min at 30 inches water back pressure |
| Flow fault |
If the pump is unable to compensate for longer than 15
seconds due to excessive back pressure, the pump enters flow fault mode.
During flow fault,
the pump enters Hold, the fault icon appears on the display during
the length of the fault, and the accumulated run time display is frozen
and retained. After 5 minutes in flow fault, auto-restart is attempted
every 5 minutes up to 10 times. |
| Run Time |
With NiMH battery pack, run time is 12+ hours for 2000 ml/min
and up to 30 inches water back pressure; dependent on sample media
used. See
Table 1.
With Battery eliminater, run time is extended |
Charging Time
(varies with battery capacity and level of discharge)
|
6 to 8.5 hrs with PowerFlex charger |
Flow accuracy |
± 5% of set-point after calibration to desired flow |
Atmospheric Pressure Accuracy |
± 0.3 in Hg |
Timing Accuracy |
1 min/mo at 25 C |
| Operating
Temperature Range |
32 to 113 F (0 to 45 C) |
Charging
Temperature Range |
50 to 113 F (10 to 45 C) |
Storage
Temperature Range |
-4 to 113 F (-20 to 45 C) |
Altitude Range |
Do not use pump beyond 7500 ft |
| Battery Pack |
Removable chargeable 4-cell NiMH battery, 4.8 V x 3.5-Ah
capacity |
| Size |
5.6 x 3 x 2.3 in
(14.2 x 7.6 x 5.8 cm) |
| Weight |
22 oz
(624 gm)
|
| Intrinsic Safety |
UL and cUL Listed
|
| Case |
Impact resistant
RFI/EMI shielded
CE marked |
Protect sample pump from weather when in use outdoors.
AirChek 2000 FAQs
Table 1: Typical Back Pressure of Sampling Media (inches water)
| Filter/Pore Size (µm) |
Flow
Rate (L/min) |
| 1.0 |
1.5 |
2.0 |
2.5 |
3.0 |
| 25-mm MCE, 0.8 |
6 |
9 |
12 |
15 |
18 |
| 25-mm MCE, 0.45 |
14 |
22 |
28 |
35 |
40 |
| 37-mm MCE, 0.8 |
2 |
3 |
4 |
5 |
6 |
| 37-mm PVC, 5.0 |
1 |
1 |
2 |
2 |
2.5 |
Compare the information in this table to pump compensation range to determine
appropriate applications.
Ordering Information
| Pumps |
Voltage |
Cat. No. |
| AirChek 2000 Pump with NiMH battery pack
and screwdriver set, requires charger, see below |
|
| AirChek 2000 Pump without Battery |
|
| Single AirChek 2000 Kit (High Flow) includes
AirChek 2000 pump, single PowerFlex charger with cable, filter cassette
holder, and soft-side nylon carry case |
100-240 V |
|
| AirChek 2000 High Flow Single Pump Kit with
Hard-side Pelican Case includes pump, single charger with cable,
filter cassette holder, and hard-side Pelican case |
100-240 V
|
|
| AirChek 2000 Starter Kit includes pump
with battery, charger, Tygon tubing (3 feet, 1/4-inch ID), and collar
clip with cable
tie |
100-240 V |
|
| 5-pack AirChek 2000 Kit (High Flow) includes 5
AirChek 2000 pumps and filter cassette holders and one 5-station
PowerFlex charger with 5 cables,in a Pelican case |
100-240 V |
|
| 5-pack AirChek 2000 Kit (High and Low Flow) includes
5-pack high flow items, 5 adjustable low flow holders, 5 constant pressure
controllers, and 5 Type A tube covers |
100-240 V |
|
5-pack AirChek 2000 High Flow CalChek Kit includes
5 pumps with NiMH batteries, 5-station PowerFlex Charger with 5 cables,
5
filter cassette holders, a CalChek
communication cable, Defender calibrator with charger, and a Pelican
carry case
|
100-240 V |
|
| Pump Certificate
|
Cat. No. |
| Certificate of Compliance, optional, must
be ordered when ordering pump |
|
| Software |
DataTrac
2000 Software Package includes software on CD, DataTrac adapter,
and DataTrac cable, Requires Windows 98 or higher and available
serial port or USB to 9-pin serial adapter that is compatible with
the PC and system
Download
DataTrac 2000 now |
|
| Calibrators and Accessories |
Defender Primary Standard Calibrator, 5 to 500 ml/min, includes
lead-acid battery, charger, Optimizer software, and 39-inch (1-meter) serial
cable
Software requires Windows XP (sp 2 or 3) or Windows Vista (32-bit version)
and an RS-232 port or USB to RS-232 adapter |
 |
|
Defender Primary Standard Calibrator, 50 to 5000
ml/min, includes lead-acid battery, multi-plug charger (100-240
V), Optimizer software, and 39-inch (1-meter) serial cable
Software
requires Windows XP (sp 2 or 3) or Windows Vista (32-bit version) and
an RS-232 port or USB to RS-232 adapter. |
 |
|
| Replacement Defender Lead-acid Battery Pack |
|
| Defender Universal Charger, 100-240 V,
with U.S., Euro, and Australia plugs |
|
| Defender Universal Charger, 100-240 V,
with U.S. plug |
|
CalChek Communication Cable, provides
direct communication between a CalChek-compatible AirChek 2000 or Leland
Legacy pump and a CalChek-capable
Defender primary standard calibrator
Note: For use only with Defender
calibrators with Revision Level C or higher
Required for CalChek calibration, included in CalChek kit above |
|
| Chargers — PowerFlex
Charging Systems |
Cat. No.
|
PowerFlex 5-station 100-240 V includes
power supply and cord
Purchase pump-specific cables separately; choose from the
list below.
For U.S.-produced pump models only, not compatible with EX and ATEX-approved
models |
 |
223-1000 |
PowerFlex Single 100-240 V includes power
supply and cord
Purchase pump-specific cables separately; choose from the
list below.
For U.S.-produced pump models only, not compatible with EX and ATEX-approved
models |
 |
223-2000 |
| Replacement CE-marked Power Supply for
5-station PowerFlex Charger |
P22310 |
|
PowerFlex Cables
|
Cat. No.
|
| PowerFlex Cable for AirChek 2000, 1 cable |
|
|
| Batteries and Battery Eliminators |
Cat. No.
|
Replacement AirChek 2000 NiMH Battery Pack
Replacing batteries with non-approved battery packs voids
the pump warranty and UL listing for intrinsic safety. |
|
Replacement AirChek 2000 NiCAD Battery Pack
Replacing batteries with non-approved battery packs voids the pump
warranty and UL listing for intrinsic safety. |
|
AC Adapter (Battery Eliminator) 115 V, connects
pump to line power for extended pump operation
Battery Eliminator should be used in non-hazardous locations only. |
 |
223-320 |
AC Adapter (Battery Eliminator) 230 V, connects
pump to line power for extended pump operation
Battery Eliminator should be used in non-hazardous locations only. |
 |
223-320B |
| Pouches and Carry Cases |
Cat. No.
|
| Protective Nylon Pump Pouch, Black with
belt and adjustable waist and shoulder strap designed for worker comfort
when using an AirChek 2000 or 52 pump |
|
|
| Protective Nylon Pump Pouch, High-profile red for
easy observation with belt and adjustable waist and shoulder strap designed
for worker comfort when using an AirChek 2000 or 52 pump |
 |
|
| Protective Nylon Pump Pouch, Black Nylon, Noise-reducing, with
belt and adjustable waist and shoulder strap designed for worker comfort
when using an AirChek 2000 or 52 pump |
 |
|
Kit Case
Single Deluxe Case (Pelican), for SKC pumps. Foam-filled case
is watertight, airtight, dustproof, and crushproof; will accommodate
a single pump and accessories |
 |
|
| Single Deluxe Case (Pelican), for
AirChek XR5000, AirChek 2000, AirChek 52, and AirLite pumps. On wheels
for easy transport, watertight, airtight, dustproof, and crushproof, equipped
with foam for complete equipment protection. |
|
|
| Sampling Accessories |
Cat. No.
|
| AirChek 2000 Low Flow (5 to 500 ml/min) Adapter Kit includes
constant pressure controller (CPC), single adjustable low flow holder,
and Type A tube cover |
 |
|
| Replacement Parts and Tools |
Cat. No.
|
| Pump Service Training Set for AirChek
2000 Pumps includes a manual and video for distributors
and customers who maintain and repair large numbers of AirChek
2000 pumps. The service video on DVD provides basic assembly/disassembly
and functional testing. |
|
| Replacement Filter/O-ring, pk/3 |
|
| Replacement Inlet/Filter Housing |
|
| SKC Pneumatic Test Kit, for testing
flow compensation in personal sample pumps, 1 to 5 L/min rotameter, 0 to
80 inches magnehelic pressure gauge. |
|
| SKC Universal Screwdriver Kit, for
use with sample pumps, includes 3 interchangeable screwdriver heads |
224-11 |
| Mini Tool Kit, for use with air sampling pumps and
filter media, includes scissors, pliers, file, 2 slotted screwdrivers,
2 Phillips screwdrivers, forceps, and charcoal pick |
 |
376-01-01
|
AirChek
2000 Spec. Sheet (PDF)
AirChek
2000 Operating Instructions (PDF)
AirChek
2000 Quick Guide (PDF)
CalChek
with the Defender Operating Instructions (PDF)
Battery
Pack for AirChek 2000 Operating Instructions (PDF)
MSDS
for Nickel Cadmium Battery GPI International (PDF)
MSDS
for Nickel Cadmium Battery SANYO Energy (PDF)
MSDS
for Nickel-metal Hydride Battery (PDF)
Technical
Note: SKC Sample Pump Battery Pack Characteristics and Maintenance (PDF)
DataTrac
2000 Software Package
UL
Certificate of Compliance (PDF)
EMC
Test Certificate (PDF)
KEMA
(Keuring van Electrotechnische Materialen) Certificate of Conformity
(PDF)
Instrucciones
de Operación (PDF)
Bedienungsanleitung
(Kurzfassung)(PDF)
Téléchargement
Guide de I'utilisateur (PDF)
Chinese
Language AirChek 2000 Operating Instructions (PDF)
This page was last modified March 17, 2010
|